BUILD THE MOTOR CONTROL CIRCUIT |
|
|
INSERT 4013 FLIP-FLOP ACROSS SLOT 1 WITH PIN
ONE AT A5 |
THIS FLIP-FLOP REMEMBERS THE FLOORS THAT HAVE
BEEN REQUESTED. |
|
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F30 AND
E30 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F27 AND
G27 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT 1K (BRN-BLK-RED) RESISTOR TO D23 AND
G24 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F1 AND G3 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F7 AND G7 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT 4.7K (YEL-VIO-RED) RESISTOR TO D4 AND
G4 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT 4.7K (YEL-VIO-RED) RESISTOR TO E7 AND
F9 |
HOLDS DOWN SWITCH INPUT |
|
CONNECT SPRING 48 AND SPRING 50 (WHITE WIRE) |
|
|
CONNECT SPRING 46 AND SPRING 48 (WHITE WIRE) |
|
|
CONNECT C2 AND D7 (WHITE WIRE) |
GROUNDS UNUSED INPUTS |
|
CONNECT C3 AND E3 (WHITE WIRE) |
GROUNDS UNUSED INPUTS |
|
CONNECT E2 AND G2 (WHITE WIRE) |
GROUNDS UNUSED INPUTS |
|
CONNECT D8 AND F8 (WHITE WIRE) |
GROUNDS UNUSED INPUTS |
|
CONNECT SPRING 11 AND SPRING 13 (WHITE WIRE) |
|
|
CONNECT SPRING 13 AND SPRING 15 (WHITE WIRE) |
|
|
CONNECT G1 AND GROUND (RED WIRE) |
GROUNDS FLIP-FLOP |
|
CONNECT D2 AND D19 (RED WIRE) |
STOPS MOTOR WHEN FLOOR IS REACHED. |
|
CONNECT E9 AND E19 (RED WIRE) |
STOPS MOTOR WHEN FLOOR IS REACHED. |
|
CONNECT A4 AND SPRING 14 (RED WIRE) |
FLOOR 1 LED |
|
CONNECT B8 AND SPRING 16 (RED WIRE) |
FLOOR 2 LED |
|
CONNECT B23 AND SPRING 12 (RED WIRE) |
MOTOR ON LED |
|
CONNECT A10 AND V6 (9 VOLTS) (RED WIRE) |
POWERS FLIP-FLOP |
|
CONNECT SPRING 46 AND V5 (7.5 VOLTS) (BLUE
WIRE) |
|
|
CONNECT SPRING 47 AND D22 (BLUE WIRE) |
STARTS MOTOR |
|
CONNECT SPRING 49 AND F3 (BLUE WIRE) |
SELECTS FLOOR 1 BY SETTING FLIP-FLOP |
|
CONNECT SPRING 51 AND G10 (BLUE WIRE) |
SELECTS FLOOR 2 BY SETTING FLIP-FLOP |
|
CONNECT SPRING 11 AND GROUND (BLUE WIRE) |
|
|
CONNECT DIODE TO F21 (+ BLACK END) AND D20 (-) |
THIS DIODE KEEPS THE STOP SIGNAL TO THE
FLIP-FLOP FROM CANCELLING THE SET ON OTHER FLOORS. |
|
CONNECT DIODE TO F22 (+ BLACK END) AND E20 (-) |
THIS DIODE KEEPS THE STOP SIGNAL TO THE
FLIP-FLOP FROM CANCELLING THE SET ON OTHER FLOORS. |
|
CONNECT G30 AND V4 TO POSITIONS 1 AND 3 ON
EXTERNAL SWITCH (1) |
THIS SWITCH SIGNALS THE FLIP-FLOP TO CHANGE THE
POLARITY OF THE MOTOR AT THE TOP OF THE ELEVATOR SHAFT. |
|
CONNECT E29 AND V4 TO POSITIONS 1 AND 3 ON
EXTERNAL SWITCH (2) |
THIS SWITCH SIGNALS THE FLIP-FLOP TO CHANGE THE
POLARITY OF THE MOTOR AT THE BOTTOM OF THE ELEVATOR SHAFT. |
|
CONNECT A1 AND D1 TO POSITIONS 1 AND 3 ON
EXTERNAL SWITCH (3) |
THIS SWITCH SIGNALS THE FLIP-FLOP THAT FLOOR 1
HAS BEEN REACHED |
|
CONNECT B10 AND E10 TO POSITIONS 1 AND 3 ON
EXTERNAL SWITCH (4) |
THIS SWITCH SIGNALS THE FLIP-FLOP THAT FLOOR 2
HAS BEEN REACHED |
|
CONNECT MOTOR TERMINALS TO Q30 AND Q21 |
|