BUILD THE MOTOR CONTROL CIRCUIT  
INSERT 4013 FLIP-FLOP ACROSS SLOT 1 WITH PIN ONE AT A5 THIS FLIP-FLOP REMEMBERS THE FLOORS THAT HAVE BEEN REQUESTED.
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F30 AND E30 HOLDS DOWN SWITCH INPUT
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F27 AND G27 HOLDS DOWN SWITCH INPUT
CONNECT 1K (BRN-BLK-RED) RESISTOR TO D23 AND G24 HOLDS DOWN SWITCH INPUT
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F1 AND G3 HOLDS DOWN SWITCH INPUT
CONNECT 1K (BRN-BLK-RED) RESISTOR TO F7 AND G7 HOLDS DOWN SWITCH INPUT
CONNECT 4.7K (YEL-VIO-RED) RESISTOR TO D4 AND G4 HOLDS DOWN SWITCH INPUT
CONNECT 4.7K (YEL-VIO-RED) RESISTOR TO E7 AND F9 HOLDS DOWN SWITCH INPUT
CONNECT SPRING 48 AND SPRING 50 (WHITE WIRE)  
CONNECT SPRING 46 AND SPRING 48 (WHITE WIRE)  
CONNECT C2 AND D7 (WHITE WIRE) GROUNDS UNUSED INPUTS
CONNECT C3 AND E3 (WHITE WIRE) GROUNDS UNUSED INPUTS
CONNECT E2 AND G2 (WHITE WIRE) GROUNDS UNUSED INPUTS
CONNECT D8 AND F8 (WHITE WIRE) GROUNDS UNUSED INPUTS
CONNECT SPRING 11 AND SPRING 13 (WHITE WIRE)  
CONNECT SPRING 13 AND SPRING 15 (WHITE WIRE)  
CONNECT G1 AND GROUND (RED WIRE) GROUNDS FLIP-FLOP
CONNECT D2 AND D19 (RED WIRE) STOPS MOTOR WHEN FLOOR IS REACHED.
CONNECT E9 AND E19 (RED WIRE) STOPS MOTOR WHEN FLOOR IS REACHED.
CONNECT A4 AND SPRING 14 (RED WIRE) FLOOR 1 LED
CONNECT B8 AND SPRING 16 (RED WIRE) FLOOR 2 LED
CONNECT B23 AND SPRING 12 (RED WIRE) MOTOR ON LED
CONNECT A10 AND V6 (9 VOLTS) (RED WIRE) POWERS FLIP-FLOP
CONNECT SPRING 46 AND V5 (7.5 VOLTS) (BLUE WIRE)  
CONNECT SPRING 47 AND D22 (BLUE WIRE) STARTS MOTOR
CONNECT SPRING 49 AND F3 (BLUE WIRE) SELECTS FLOOR 1 BY SETTING FLIP-FLOP
CONNECT SPRING 51 AND G10 (BLUE WIRE) SELECTS FLOOR 2 BY SETTING FLIP-FLOP
CONNECT SPRING 11 AND GROUND (BLUE WIRE)  
CONNECT DIODE TO F21 (+ BLACK END) AND D20 (-)  THIS DIODE KEEPS THE STOP SIGNAL TO THE FLIP-FLOP FROM CANCELLING THE SET ON OTHER FLOORS.
CONNECT DIODE TO F22 (+ BLACK END) AND E20 (-)  THIS DIODE KEEPS THE STOP SIGNAL TO THE FLIP-FLOP FROM CANCELLING THE SET ON OTHER FLOORS.
CONNECT G30 AND V4 TO POSITIONS 1 AND 3 ON EXTERNAL SWITCH (1) THIS SWITCH SIGNALS THE FLIP-FLOP TO CHANGE THE POLARITY OF THE MOTOR AT THE TOP OF THE ELEVATOR SHAFT.
CONNECT E29 AND V4 TO POSITIONS 1 AND 3 ON EXTERNAL SWITCH (2) THIS SWITCH SIGNALS THE FLIP-FLOP TO CHANGE THE POLARITY OF THE MOTOR AT THE BOTTOM OF THE ELEVATOR SHAFT.
CONNECT A1 AND D1 TO POSITIONS 1 AND 3 ON EXTERNAL SWITCH (3) THIS SWITCH SIGNALS THE FLIP-FLOP THAT FLOOR 1 HAS BEEN REACHED
CONNECT B10 AND E10 TO POSITIONS 1 AND 3 ON EXTERNAL SWITCH (4) THIS SWITCH SIGNALS THE FLIP-FLOP THAT FLOOR 2 HAS BEEN REACHED
CONNECT MOTOR TERMINALS TO Q30 AND Q21